Evaluation of PET/MR Enterography for Differentiation of Fibrotic and Inflammatory Strictures in Patients With Crohn's Disease Using a Collagen-binding Radiotracer.
Massachusetts General Hospital
Summary
In this study twenty-five (25) subjects with Crohn's disease scheduled for possible surgical intervention will be recruited for this study and a PET/MR scan using the collagen-binding radiotracer will be performed. The study aims to establish the performance figures of PET/MR using \[68Ga\]CBP8-PET for preoperative detection and differentiation of strictures with a fibrotic component in patients with Crohn's disease by using surgical and histologic findings (when available) as the standard for comparison. Furthermore, the investigators will determine the performance figures with which strictures are identified and characterized by PET/MR using \[68Ga\]CBP8-PET compared to each modality in isolation (PET alone or MR alone). Blood and tissue markers for fibrostenosis will be explored (either predictive or as biomarkers for fibrotic burden), using histologic and molecular testing by using surgical and histologic findings (when available) as the standard for comparison. Lastly the investigators want to determine the performance figures with which strictures are identified and characterized by PET/MR using \[68Ga\]CBP8-PET compared to each modality in isolation (PET alone or MR alone).
Description
Inflammatory bowel disease (IBD) is a common disease affecting over 1.4 million Americans. IBD is generally further classified into one of two distinct pathologic entities: Crohn's disease and ulcerative colitis \[1\]. Inflammation spanning the wall of the bowel in Crohn's disease predisposes to intestinal stricture formation, which can lead to significant morbidity. Strictures in Crohn's disease are generally classified as inflammatory, fibrotic, or mixed. Differentiation between these categories has important clinical ramifications, as medical therapy is the preferred initial treatment for s…
Eligibility
- Age range
- 18–99 years
- Sex
- All
- Healthy volunteers
- No
Inclusion Criteria: * Age greater than 18 years * Biopsy confirmed/suspected Crohn's disease * Ability to give written informed consent Exclusion Criteria: * Electrical implants such as cardiac pacemaker or perfusion pump; * Ferromagnetic implants such as aneurysm clips, surgical clips, prostheses, artificial hearts, valves with steel parts, metal fragments, shrapnel, metallic tattoos anywhere on the body, tattoos near the eye, or steel implants ferromagnetic objects such as jewelry or metal clips in clothing; * eGFR of less than 30 mL/min/1.73 m2 within the past 90 days; * Pregnant or brea…
Interventions
- DrugRadiotracer Injection
Injection of Gallium-68 labeled collagen binding probe 8 (\[68Ga\]CBP8): All subjects will undergo placement of an intravenous catheter (IV). The catheter will be flushed post-injection of \[68Ga\]CBP8 with 0.9% saline solution. The subjects will be positioned on the scanner table; support devices under the back and/or legs will be used as needed to enable the patient to comfortably maintain his/her position throughout the scan; Up to 15 mCi of \[68Ga\]CBP8 will be administered. The injected dose and the time of injection will be recorded; Post scan: The catheter will be removed. The subject will be asked to void again immediately after the scan and he/she will be counseled on the importance of continuing to drink fluids for several more hours in order to increase urine flow rate and minimize the radiation dose to the bladder wall.
- DrugContrast Media, Magnetic Resonance
Dotarem 20ml will be injected during acquisition of contrast enhanced T1weighted fat saturated sequences, in keeping with standard of care MR enterography.
- Diagnostic TestBlood Draw
All subjects will undergo placement of an intravenous catheter (IV). Through the same catheter, 10 mL of venous blood will be collected to evaluate blood markers for fibrostenosis.
- DrugGlucagon
Glucagon will be injected into the subject's indwelling i.v. catheter (0.3-0.5 mg) before imaging acquisition; or intramuscularly (1-2 mg) prior to imaging the abdomen and pelvis. A second administration of IV glucagon (0.3-0.5mg) may take place during image acquisition.
- Diagnostic TestImaging
MR and PET images of the abdomen and pelvis will be acquired using the Siemens 3 Tesla Biograph mMR scanner. Multiple anatomical and functional imaging sequences may be run to assess specific image quality measures in addition to those used for anatomical diagnosis. Among the sequences, patients will undergo a full set of standard of care MR enterography sequences to ensure they get at least same quality of study and of clinical information they would gain from a clinical study. Certain MR sequences scans may be repeated after varying a limited range of pulse sequence parameters to assess their effect on the image contrast, image artifacts and signal to noise ratio.
- DrugOral contrast media application
Patients will be invited to drink as much as possible of an oral contrast solution consisting of a mixture of 1500-2000 ml of dilute barium or sorbitol (VoLumen or Breeza) and water. Breeza, and in the past VoLumen, is routine clinical practice at MGH. The solution comes already prepared in bottles, so there is no need to dilute or prepare. The investigators will just hand the bottle to the patient and will ask the patient to start drinking \~1 hour before the scan. By routine practice at MGH, the investigators give 3-4 bottles of Breeza, about 1500-2000ml.