A Prospective, Randomized, Dual-arm Multi-center Study to Assess the Safety and Effectiveness of Mechanical Thrombectomy Using the Anaconda ANA Funnel Catheter in Combination With a Stent Retriever
Anaconda Biomed S.L.
Summary
The objective of this study is to assess the safety and effectiveness of mechanical thrombectomy (MT) using the ANA funnel catheter in its intended use, which is to facilitate the navigation and deployment of other neurovascular devices and to allow flow arrest during mechanical thrombectomy procedures performed in subjects experiencing acute ischemic stroke (AIS) secondary to large vessel occlusion (LVO) and treated within 24 hours of symptom onset.
Description
Similar to other ancillary devices used in MT, the ANA device is designed to facilitate the delivery of stent retrievers and other catheters during these procedures. Its design aims to enhance procedural success and the efficiency of stent retriever-based MT by enabling flow arrest during clot retrieval. This approach has been shown to improve rates of revascularization and favorable clinical outcomes at three months. The use of the ANA to facilitate MT with a stent retriever may provide a simplified approach to flow restriction and could achieve acute reperfusion outcomes comparable to commo…
Eligibility
- Age range
- 22–85 years
- Sex
- All
- Healthy volunteers
- No
Key Inclusion Criteria: Subjects meeting all inclusion criteria will be considered for enrollment in the study. 1. Age 22 to 85 years. 2. Informed consent was obtained from subject or acceptable subject surrogate (e.g., next of kin, or legal representative). 3. A new focal disabling neurologic deficit consistent with acute cerebral ischemia. 4. Baseline NIHSS obtained prior to procedure ≥ 6 points and ≤ 25 points. 5. Pre-ictal mRS score of 0,1 or 2. 6. Treatable within 16 hours of symptom onset, defined as point in time when the subject was last observed to be asymptomatic; treatment start i…
Interventions
- DeviceANA Funnel Catheter
Mechanical thrombectomy using a stent retriever delivered by the ANA device that enables local flow restriction when deployed.
- DeviceControl
Mechanical thrombectomy using a stent retriever delivered by an approved guide catheter with or without an intermediate catheter and aspiration per conventional techniques.