Massachusetts General Hospital
This study aims to determine if PET/MRI can detect endometriosis and potentially improve upon currently available non-invasive diagnostic capabilities. Specifically, the authors will investigate the ability of PET/MRI to detect and quantify endometriosis, as well as differentiate among subcategories such as inflammatory peritoneal lesions, fibrotic deep infiltrating endometriosis lesions (DIE), and ovarian endometriomas. The authors will compare \[68Ga\]CBP8 or \[18F\]-FAPI-74 PET/MRI imaging versus the current gold standard diagnostic methods, including laparoscopic surgery, clinical follow-up, and follow-up imaging.
Several imaging techniques, including ultrasound, computed tomography and magnetic resonance imaging (MRI), have been used for the detection of DIE, for mapping and staging endometriosis. Currently, the modalities most commonly used are transvaginal ultrasound (TVS) and magnetic resonance imaging MRI. TVS is generally considered a first-line technique.TVS, in highly experienced hands, meets the criteria for mapping DIE to the uterosacral ligaments, rectovaginal septum, vaginal wall, pouch of Douglas and rectosigmoid; however it is limited by its operator dependance and by the small field of vi…
Inclusion Criteria: \- Patients with clinical diagnosis of endometriosis, in any stage, candidate for diagnostic overtherapeutic laparoscopic surgery. Exclusion Criteria: * Subjects less than 18 years of age or greater than 70 years of age. * Any contraindication to MRI, including electrical implants, such as cardiac pacemakers or perfusion pumps. MRI non-compatible ferromagnetic implants such as aneurysm clips, surgical clips, prostheses, artificial hearts, prosthetic heart valves that are not compatible with the gradient maps of our scanners, metal fragments, shrapnel, metallic tattoos an…
An intravenous catheter will be placed in an arm or hand vein for injection of \[68Ga\]CBP8; 6-10 mCi of \[68Ga\]CBP8 or 5-9 mCi of FAPI will be injected into the Biograph mMR system. The injected dose and the time of injection will be recorded; The catheter will be flushed with 0.9% saline solution; The subjects will then be positioned on the scanner table; support devices under the back or legs will be used to enable the patient to maintain his/her position throughout the scan comfortably.
MRI and PET scanner to be used: 3.0 T Laboratory (Bay 7) Siemens Biograph mMR. Magnetic resonance images of the pelvis and abdomen will be acquired using the Martinos Center's combined 3 Tesla PET/MRI scanner. The image quality on these 3 Tesla devices will be very high, equivalent to or better than any other standard clinical MRI system. PET images of the target body site will be acquired when necessary, the data acquisition will be started shortly before radiotracer injection; Coincidence event data will be acquired and stored in list mode or compressed (i.e., sinogram space) format. Subjects will be asked to lie still for the duration of the study. The entire imaging session will last up to 120 minutes
About 50ml of ultrasound gel will be placed into the vagina using the blunt end of the ultrasound gel tube or a Foley catheter or a syringe with a blunt Christmas tree end. No ultrasound probe will be inserted into the vagina, no external ultrasound probe will be used. No ultrasound study will be performed. The ultrasound gel will only be used to distend the vagina and improve the quality of MRI images; this is standard of practice in MRI for endometriosis and for several other gynecological diseases.