Effect of Clear Aligner Attachment Size on Extrusion of Maxillary Lateral Incisors
Virginia Commonwealth University
Summary
Orthodontic treatment has been revolutionized by clear aligner therapy, offering patients a more esthetic and comfortable alternative to traditional braces. In 1999, Align Technology introduced Invisalign. As Invisalign has increased in popularity and demand over the past two decades, clinical trials have shed light on the efficacy of Invisalign treatment. there have been changes in the Invisalign protocol such as introduction of SmartForce features in 2008, such as optimized attachments as well as the implementation of SmartTrack aligner material in 2011. Compared to conventional fixed orthodontic appliances, Invisalign cannot be adjusted on a visit-to visit basis. If ideal tooth movement has not been achieved after completion of the first sequence of aligners, additional trays, known as refinement trays, are required.
Description
There are various expert theories regarding the most effective methods of extrusion and multiple studies performed in vitro to evaluate the efficacy of different attachment types on the extrusion of lateral incisors, however only one in vivo clinical trial exists. There is a need for more randomized clinical trials that evaluate the effectiveness of different attachment designs for achieving optimal extrusion of lateral incisors. By determining the most effective attachment size for maxillary lateral incisor extrusion, this study can help improve treatment outcomes for orthodontic treatment wi…
Eligibility
- Age range
- 12+ years
- Sex
- All
- Healthy volunteers
- No
Inclusion Criteria: * Patients treated with either Comprehensive Invisalign or Invisalign Teen treatment * The maxillary arch has less than 6 mm of crowding or spacing * Maxillary lateral incisors have a minimum of 0.3 mm of extrusion prescribed in the Tooth Movement Table on the Invisalign ClinCheck for the first set of aligners * Maxillary lateral incisors within a normal range of bucco-lingual inclination * Patients 12 years of age or older and either the patient or legal guardian are able to give consent * Patients confirm good compliance throughout the study period Exclusion Criteria:…
Interventions
- DeviceCorresponding treatment order in the prescription with Align Technology
Treating orthodontist placing the corresponding order in the prescription with Align Technology.
- DeviceSuperimposition of final and initial positions of lateral incisors: Predicted model
Superimposition of final and initial positions of lateral incisors, two superimpositions will be completed. The pretreatment model will be superimposed with the predicted final model to establish the predicted movement of the maxillary lateral incisors
- DeviceSuperimposition of final and initial positions of lateral incisors: Gingivally beveled 1x1x3mm aligners
Superimposition of final and initial positions of lateral incisors, two superimpositions will be completed. The pretreatment model (Gingivally beveled 1x1x3mm aligners) will be superimposed with the posttreatment model to establish the actual movement of the maxillary lateral incisor.
- DeviceSuperimposition of final and initial positions of lateral incisors: Gingivally beveled 1x1x4mm aligners
Superimposition of final and initial positions of lateral incisors, two superimpositions will be completed. The pretreatment model (Gingivally beveled 1x1x4mm aligners) will be superimposed with the posttreatment model to establish the actual movement of the maxillary lateral incisor.
Location
- Virginia Commonwealth UniversityRichmond, Virginia