The Validation of Minimally Invasive Oxygen Nanosensor Technology to Quantify Mitochondrial Function in Human Muscle
Children's Hospital of Philadelphia
Summary
Past mitochondrial disease treatment studies have been unsuccessful in determining treatment efficacy, and a major factor has been the lack of validated biomarkers in mitochondrial myopathy (MM). There is currently a growing number of potential new treatments to be tested through MM clinical intervention trials, which has created a pressing need for quantitative biomarkers that reliably reflect MM disease severity, progression, and therapeutic response. The purpose of the study is to measure the efficacy of an electrochemical oxygen nanosensor to measure in vivo mitochondrial function in human muscle tissue, and its ability to discriminate MM patients from healthy volunteers. The data and results from this nanosensor study may contribute to current and future research, including improved diagnostic and therapeutic approaches for patients with mitochondrial disease.
Description
This is an investigational device clinical trial. Mitochondrial Myopathy (MM) cases and healthy volunteers will undergo nanosensor muscle oxygen measurement in exercised (dominant) forearm muscle during handgrip exercise. After placement of the nanosensor in the forearm under local anesthesia, the primary outcome measure is nanosensor-muscle oxygen levels. The secondary outcome measure is an assessment of pain.
Eligibility
- Age range
- 18–65 years
- Sex
- All
- Healthy volunteers
- Yes
Inclusion Criteria: * Inclusion Criteria for Healthy Controls 1. Males and females, between the ages of 18 and 65 years, inclusive 2. Provide informed consent for study participation; able to understand and complete the protocol 3. Able to ambulate independently 4. Able to perform bicycle ergometry Inclusion Criteria for Mitochondrial Myopathy (MM) Cases 1. Males and females, between the ages of 18 and 65 years, inclusive 2. Provide informed consent for study participation; able to understand and complete the protocol 3. Genetically-confirmed MM as defined by a diagnosis of primary…
Interventions
- DeviceNanosensor
The purpose of the study is to test a device called a "nanosensor", which measures oxygen levels (a proxy of mitochondrial function) in muscle. The nanosensor has not been tested in humans nor has it been approved by the FDA. The study nanosensor measures 1.8 mm width x 6 mm length x 0.3 mm depth. Placement of the sterilized nanosensor involves a small incision for manual placement of the nanosensor in muscle forearm tissue.