Aptitude Medical Systems
The Metrix CT/NG/TV Test will be evaluated for use in Non-Laboratory settings in a home testing environment utilizing the clinical study design described herein. The study will take place in simulated home environments which will be set up within or near active clinical settings (e.g., urgent care facilities). This will be a prospective study conducted at three or more investigational sites located within the United States for the clinical validation of the Metrix CT/NG/TV Test for the detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis from vaginal swab samples. Additional sites may be added to the study in order to meet minimum subject/sample enrollment requirements and geographic prevalence of STIs. Comparator testing will be performed to determine the infection status of each sample for comparison to results generated by the candidate test. The patient infectious status will be determined with two separate FDA-cleared assays for the detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis.
The Metrix CT/NG/TV Test will be evaluated for OTC use in a home use testing environment utilizing the clinical study design described herein. The study will take place in simulated home environments which will be set up within or near active clinical settings (e.g., urgent care facilities). This will be a prospective study conducted at three or more investigational sites located within the United States for the clinical validation of the Metrix Respiratory Panel Test for the differential detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis from vaginal swab sam…
Inclusion Criteria: * 1\. Subject is willing and able to give voluntary written informed consent (and assent, if under age 18) before any study-related procedure is performed. * 2\. Subject was assigned female sex at birth. (Pregnant and breastfeeding subjects are eligible.) * 3\. Subject is aged 14 years or older at the time of enrollment. * 4\. Subject is sexually active within the last 6 months. * 5\. Subject is suspected of having an infection with Chlamydia trachomatis, Neisseria gonorrhoeae, and/or Trichomonas vaginalis or has had recent sexual contact with an individual known or suspec…
The Metrix CT/NG/TV Test is a real-time reverse transcription loop-mediated isothermal amplification reaction (RT-LAMP) test that has been designed to detect DNA from Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis via electrochemical detection using the Metrix Reader. Detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Trichomonas vaginalis gene targets will produce a positive result, differentiated by each target. If no target is detected and the internal control amplifies, the result is negative. If no amplification is detected in any of the channels, an invalid result is displayed.